<s>
The	O
PowerEdge	B-Device
is	O
a	O
server	O
line	O
by	O
Dell	O
,	O
following	O
the	O
naming	O
convention	O
for	O
other	O
Dell	O
products	O
:	O
the	O
PowerVault	B-Device
(	O
data	O
storage	O
)	O
and	O
the	O
PowerConnect	B-Operating_System
(	O
data	O
transfer	O
&	O
switches	O
)	O
.	O
</s>
<s>
Below	O
is	O
an	O
overview	O
of	O
current	O
and	O
former	O
servers	B-Application
within	O
Dell	O
's	O
PowerEdge	B-Device
product	O
line	O
.	O
</s>
<s>
Different	O
models	O
are	O
or	O
were	O
available	O
as	O
towers	O
,	O
19-inch	B-Application
racks	I-Application
or	O
blades	B-Architecture
.	O
</s>
<s>
In	O
the	O
current	O
naming	O
scheme	O
,	O
towers	O
are	O
designated	O
by	O
T	O
,	O
racks	O
by	O
R	O
,	O
and	O
blades	B-Architecture
by	O
M	O
(	O
for	O
modular	O
)	O
.	O
</s>
<s>
The	O
19″	O
rack-servers	O
come	O
in	O
different	O
physical	O
heights	O
expressed	O
in	O
rack	O
units	O
or	O
U	O
.	O
</s>
<s>
Most	O
modern	O
servers	B-Application
are	O
either	O
1U	O
or	O
2U	O
high	O
while	O
in	O
the	O
past	O
the	O
4U	O
was	O
more	O
common	O
.	O
</s>
<s>
Over	O
the	O
years	O
,	O
many	O
different	O
types	O
of	O
PowerEdge	B-Device
servers	B-Application
have	O
been	O
introduced	O
and	O
there	O
was	O
wide	O
variety	O
of	O
product	O
and	O
family	O
codes	O
used	O
within	O
the	O
PowerEdge	B-Device
name	O
.	O
</s>
<s>
The	O
Dell	O
Itanium-based	O
servers	B-Application
were	O
introduced	O
before	O
this	O
new	O
naming-convention	O
was	O
introduced	O
and	O
were	O
only	O
available	O
as	O
rack	O
servers	B-Application
.	O
</s>
<s>
Since	O
the	O
introduction	O
of	O
the	O
Generation	O
10	O
servers	B-Application
in	O
2007	O
Dell	O
has	O
adopted	O
a	O
standardized	O
method	O
for	O
naming	O
their	O
servers	B-Application
;	O
the	O
name	O
of	O
each	O
server	O
is	O
now	O
represented	O
by	O
a	O
letter	O
followed	O
by	O
3	O
digits	O
.	O
</s>
<s>
The	O
letter	O
indicates	O
the	O
type	O
of	O
server	O
:	O
R	O
(	O
for	O
Rack-mountable	B-Application
)	O
indicates	O
a	O
19″	O
rack-mountable	B-Application
server	O
,	O
M	O
(	O
for	O
Modular	O
)	O
indicates	O
a	O
blade	B-Architecture
server	I-Architecture
,	O
whilst	O
T	O
(	O
for	O
Tower	O
)	O
indicates	O
a	O
stand-alone	O
server	O
.	O
</s>
<s>
For	O
example	O
:	O
The	O
Dell	B-Device
PowerEdge	I-Device
M610	O
is	O
a	O
two-socket	O
blade	B-Architecture
server	I-Architecture
of	O
the	O
11th	O
generation	O
using	O
an	O
Intel	O
CPU	O
.	O
</s>
<s>
For	O
example	O
:	O
The	O
Dell	B-Device
PowerEdge	I-Device
R6415	O
model	O
is	O
a	O
rack	O
,	O
mid-range	O
,	O
14th	O
generation	O
,	O
single	O
CPU	O
socket	O
system	O
with	O
AMD	O
Processor	O
.	O
</s>
<s>
Since	O
Generation	O
10	O
there	O
are	O
models	O
for	O
the	O
M1000e	B-Application
enclosure	O
.	O
</s>
<s>
The	O
blade-servers	O
in	O
Generation	O
8	O
and	O
Generation	O
9	O
are	O
using	O
another	O
enclosure	O
that	O
is	O
not	O
compatible	O
with	O
the	O
current	O
M1000e	B-Application
system	O
.	O
</s>
<s>
In	O
an	O
enclosure	O
you	O
can	O
fit	O
8	O
full	O
or	O
16	O
half-height	O
blades	B-Architecture
(	O
or	O
a	O
mix	O
)	O
.	O
</s>
<s>
Each	O
server	O
has	O
two	O
or	O
four	O
on-board	O
NIC	O
's	O
and	O
two	O
additional	O
Mezzanine	O
card-slots	O
for	O
additional	O
I/O	B-General_Concept
options	O
:	O
1Gb	O
or	O
10Gb	O
Ethernet	O
cards	O
,	O
Fibre	B-Architecture
Channel	I-Architecture
HBA	B-Architecture
's	O
or	O
InfiniBand	B-Architecture
slots	O
.	O
</s>
<s>
Apart	O
from	O
USB	B-Protocol
connectors	O
a	O
blade-server	O
does	O
n't	O
offer	O
direct	O
connections	O
:	O
all	O
I/O	B-General_Concept
goes	O
via	O
the	O
midplane	O
of	O
the	O
enclosure	O
.	O
</s>
<s>
&	O
Socket	O
)	O
CPU	O
(	O
Type	O
)	O
RAM	O
(	O
Max	O
)	O
RAM	O
(	O
Type	O
)	O
Drive	O
bays	O
Comments	O
350Dell	O
PowerEdge	B-Device
350	O
Technical	O
Specification	O
1U	O
Rack	O
circa	O
2001	O
Intel	O
440BX	O
Pentium	O
III	O
650Mhz-1.0Ghz	O
orCeleron	O
600+	O
1	O
GB	O
4	O
,	O
SDRAM	O
unbuffered	O
and	O
registered	B-General_Concept
PC-100	O
(	O
2	O
)	O
int	O
.	O
</s>
<s>
&	O
Socket	O
)	O
CPU	O
(	O
Type	O
)	O
RAM	O
(	O
Max	O
)	O
RAM	O
(	O
Type	O
)	O
Drive	O
bays	O
Comments	O
800Dell	O
PowerEdge	B-Device
800	O
Specification	O
Sheet	O
Tower	O
2005	O
Intel	O
E7221	O
1	O
LGA	B-Device
775	I-Device
Pentium	O
4	O
up	O
to	O
3.8	O
GHz	O
or	O
Celeron	O
up	O
to	O
2.53	O
GHz	O
4	O
GB	O
4	O
,	O
ECC	B-Error_Name
DDR2	O
400/533	O
4	O
×	O
1″	O
SCSI	O
or	O
SATA	O
830Dell	O
PowerEdge	B-Device
830	O
Specification	O
Sheet	O
Tower	O
2005	O
Intel	O
E7230	O
1	O
LGA	B-Device
775	I-Device
Pentium	O
D	O
up	O
to	O
3.2	O
GHz	O
or	O
Pentium	O
4	O
up	O
to	O
3.6	O
GHz	O
or	O
Celeron	O
D	O
2.53	O
GHz	O
8	O
GB	O
4	O
,	O
ECC	B-Error_Name
DDR2	O
533-667	O
4	O
×	O
HDD	O
bays	O
840	O
(	O
Gen	O
I	O
,	O
II	O
)	O
Dell	B-Device
PowerEdge	I-Device
840	O
Specification	O
SheetPowerEdge	O
840	O
A08	O
BIOS	O
Release	O
Notes	O
Tower	O
2006	O
Intel	O
3000	O
1	O
LGA	B-Device
775	I-Device
Xeon	B-Device
X3200	O
(	O
Gen	O
II	O
only	O
)	O
,	O
Xeon	B-Device
3000	O
,	O
Pentium	O
or	O
Celeron	O
8	O
GB	O
4	O
,	O
ECC	B-Error_Name
DDR2	O
533-667	O
2	O
×	O
5.25	O
″	O
ext.1	O
×	O
3.5	O
″	O
ext.4	O
×	O
3.5	O
″	O
int	O
.	O
</s>
<s>
Model	O
Chassis	O
Year	O
Chipset	O
CPU	O
Sockets	O
CPU	O
RAM	O
(	O
Max	O
)	O
RAM	O
(	O
Type	O
)	O
Drive	O
bays	O
Comments	O
850Dell	O
PowerEdge	B-Device
850	O
Info	O
brief	O
1U	O
Rack	O
2005	O
Intel	O
E7230	O
1	O
LGA	O
775Intel	O
Pentium	O
4	O
(	O
up	O
to	O
3.8	O
GHz	O
)	O
or	O
Celeron	O
(	O
2.53	O
GHz	O
)	O
or	O
Pentium	O
D	O
dual-core	O
(	O
up	O
to	O
3.2	O
GHz	O
)	O
8	O
GB	O
4	O
,	O
ECC	B-Error_Name
DDR2	O
533/667	O
MHz	O
2	O
×	O
3.5	O
″	O
SATA	O
or	O
SCSI	O
860	O
(	O
Gen	O
I	O
,	O
II	O
)	O
Dell	B-Device
PowerEdge	I-Device
860	O
Specification	O
SheetPowerEdge	O
860	O
A05	O
BIOS	O
Release	O
Notes	O
1U	O
Rack	O
2006	O
Intel	O
3000	O
1	O
LGA	O
775Celeron	O
D	O
,	O
Pentium	O
D	O
925	O
,	O
Celeron	O
430/440	O
,	O
Pentium	O
Dual-Core	O
E2160	O
,	O
Core	O
2	O
Duo	O
E4400	O
,	O
Xeon	B-Device
3000	O
,	O
Xeon	B-Device
3200	O
8	O
GB	O
4	O
,	O
ECC	B-Error_Name
DDR2	O
533/667	O
MHz	O
2	O
×	O
3.5	O
″	O
SATA	O
or	O
SAS	O
and	O
1	O
×	O
slim	O
optical	O
The	O
PE	O
850	O
and	O
860	O
share	O
chassis	O
with	O
the	O
R200	O
,	O
and	O
other	O
than	O
name	O
badge	O
are	O
visually	O
identical	O
.	O
</s>
<s>
1900Dell	O
PowerEdge	B-Device
1900	O
Specification	O
Sheet	O
Tower	O
2006	O
Intel	O
5000P	O
2	O
LGA	B-Device
771	I-Device
Xeon	B-Device
5000	O
,	O
5100	O
or	O
5300	O
16	O
GB	O
8	O
,	O
DDR2	O
533/667	O
MHz	O
FB-DIMM	O
6	O
×	O
3.5	O
″	O
SAS/SATA	O
and	O
1	O
×	O
Peripheral	O
bay	O
and	O
1	O
×	O
3.5	O
″	O
floppy	O
This	O
model	O
replaces	O
the	O
1800	O
.	O
</s>
<s>
Peripheral	O
bay	O
can	O
hold	O
2	O
×	O
5.25	O
″	O
devices	O
1950	O
(	O
Gen	O
I	O
,	O
II	O
,	O
III	O
)	O
Dell	B-Device
PowerEdge	I-Device
1950	O
Specification	O
Sheet	O
1U	O
Rack	O
2006	O
Intel	O
5000X	O
2	O
LGA	B-Device
771	I-Device
GI	O
:	O
Xeon	B-Device
5000	O
,	O
5100GII	O
:	O
Xeon	B-Device
5000	O
,	O
5100	O
,	O
5300GIII	O
:	O
Xeon	B-Device
5000	O
,	O
5100	O
,	O
5200	O
,	O
5300	O
,	O
5400	O
GI	O
&	O
GII	O
:	O
32	O
GB	O
;	O
GIII	O
:	O
64	O
GB	O
GI	O
&	O
GII	O
:	O
8	O
,	O
ECC	B-Error_Name
DDR2	O
533/667	O
MHz	O
FB-DIMMGIII	O
:	O
8	O
,	O
ECC	B-Error_Name
DDR2	O
667	O
MHz	O
FB-DIMM	O
2	O
×	O
3.5	O
″	O
SAS/SATA	O
or	O
4	O
×	O
2.5	O
″	O
SAS	O
and	O
1	O
×	O
slim	O
optical	O
1955Dell	O
PowerEdge	B-Device
1955	O
Specification	O
Sheet	O
Blade	O
2006	O
Intel	O
5000P	O
2	O
LGA	B-Device
771	I-Device
Xeon	B-Device
5000	O
,	O
5100	O
or	O
5300	O
32	O
GB	O
8	O
,	O
ECC	B-Error_Name
DDR2	O
FB-DIMM	O
2	O
×	O
2.5	O
″	O
SAS/SATA	O
Uses	O
same	O
blade	O
chassis	O
as	O
1855	O
.	O
</s>
<s>
Up	O
to	O
10	O
blades	B-Architecture
2900	O
(	O
Gen	O
I	O
,	O
II	O
,	O
III	O
)	O
Dell	B-Device
PowerEdge	I-Device
2900	O
Specification	O
Sheet	O
Tower	O
or	O
5U	O
2006	O
Intel	O
5000X	O
2	O
LGA	B-Device
771	I-Device
Xeon	B-Device
5000	O
,	O
5100	O
,	O
5300	O
or	O
5400	O
48	O
GB	O
12	O
,	O
ECC	B-Error_Name
DDR2	O
533/667	O
MHz	O
FB-DIMM	O
8	O
×	O
3.5	O
″	O
SAS/SATA	O
and	O
1	O
×	O
Flexbay	O
and	O
1	O
×	O
Peripheral	O
bay	O
and	O
1	O
×	O
3.5	O
″	O
floppy	O
Flexbay	O
can	O
hold	O
2	O
×	O
3.5	O
″	O
HDD	O
.	O
</s>
<s>
Peripheral	O
bay	O
can	O
hold	O
2	O
×	O
5.25	O
″	O
devices	O
2950	O
(	O
Gen	O
I	O
,	O
II	O
,	O
III	O
)	O
Dell	B-Device
PowerEdge	I-Device
2950	O
Specification	O
SheetDell	O
PowerEdge	B-Device
2950	O
III	O
Specification	O
Sheet	O
2U	O
Rack	O
2006	O
Intel	O
5000X	O
2	O
LGA	B-Device
771	I-Device
GI	O
:	O
Xeon	B-Device
5000	O
,	O
5100GII	O
:	O
Xeon	B-Device
5000	O
,	O
5100	O
,	O
5300GIII	O
:	O
Xeon	B-Device
5000	O
,	O
5100	O
,	O
5200	O
,	O
5300	O
,	O
5400	O
GI	O
:	O
32	O
GB	O
;	O
GIIDell	O
PowerEdge	B-Device
1950/2950	O
Memory	O
Capacity	O
&	O
GIII	O
:	O
64	O
GB	O
GI	O
&	O
GII	O
:	O
8	O
,	O
ECC	B-Error_Name
DDR2	O
533/667	O
MHz	O
FB-DIMMGIII	O
:	O
8	O
,	O
ECC	B-Error_Name
DDR2	O
667	O
MHz	O
FB-DIMM	O
8	O
×	O
2.5	O
″	O
SAS	O
and	O
1	O
×	O
Peripheral	O
bay	O
or	O
4	O
×	O
3.5	O
″	O
SAS/SATA	O
and	O
1	O
×	O
Peripheral	O
bay	O
or	O
6	O
×	O
3.5	O
″	O
SAS/SATA	O
and	O
1	O
×	O
slim	O
optical	O
All	O
configurations	O
include	O
1	O
×	O
slim	O
optical	O
drive	O
.	O
</s>
<s>
In	O
March	O
2012	O
Dell	O
introduced	O
their	O
12th	O
generation	O
servers	B-Application
based	O
on	O
Intel	B-Device
Xeon	I-Device
.	O
</s>
<s>
On	O
the	O
720	O
line	O
,	O
Dell	O
currently	O
offers	O
two	O
rack-model	O
servers	B-Application
:	O
the	O
Poweredge	B-Device
R720	O
and	O
the	O
R720XD	O
where	O
the	O
latter	O
offers	O
the	O
option	O
to	O
extend	O
the	O
system	O
to	O
up	O
to	O
26	O
internal	O
disks	O
.	O
</s>
<s>
The	O
Poweredge	B-Device
620	O
series	O
offer	O
models	O
for	O
rack	O
,	O
tower	O
and	O
a	O
½	O
height	O
blade-server	O
M620	O
.	O
</s>
<s>
A	O
½	O
height	O
blade	O
means	O
that	O
you	O
can	O
fit	O
up	O
to	O
16	O
of	O
those	O
servers	B-Application
in	O
one	O
M1000e	B-Application
enclosure	O
.	O
</s>
<s>
The	O
M520	O
and	O
M620	O
can	O
also	O
be	O
used	O
in	O
the	O
new	O
PowerEdge	B-Device
VRTX	I-Device
system	O
.	O
</s>
<s>
The	O
new	O
M420	O
is	O
1/4	O
height	O
,	O
so	O
32	O
fit	O
in	O
a	O
M1000e	B-Application
chassis	O
but	O
does	O
require	O
a	O
special	O
full	O
height	O
holder	O
that	O
fits	O
4	O
M420	O
's	O
in	O
one	O
full-height	O
(=	O
double	O
)	O
slot	O
.	O
</s>
<s>
It	O
offers	O
more	O
or	O
less	O
the	O
same	O
functionality	O
as	O
a	O
network-enabled	O
KVM	B-Device
switch	I-Device
,	O
but	O
with	O
some	O
additional	O
options	O
.	O
</s>
<s>
or	O
10	O
×	O
2.5	O
″	O
3	O
:	O
2	O
-	O
x16	O
FH/FL	O
,	O
1	O
-	O
x8	O
FH/FL	O
or2	O
,	O
2	O
x	O
x16	O
Broadcom	O
or	O
Intel	O
4×	O
1Gb	O
or	O
2×	O
10Gb	O
R720	O
2U	O
Rack	O
2012	O
C600	B-Architecture
2	O
LGA	B-Device
2011	I-Device
Xeon	B-Device
E5-2600or	O
E5-2600	O
v2	O
1.5	O
TB	O
24	O
,	O
DIMMDDR3	O
,	O
1600Mhz	O
25	O
TB	O
8	O
×	O
3.5	O
″	O
or	O
16	O
×	O
2.5	O
″	O
7	O
:	O
1x16	O
FH/FL	O
,	O
3x8	O
FH/FL	O
,	O
3x8	O
HH/HL	O
Broadcom	O
or	O
Intel	O
4×	O
1Gb	O
or	O
2×	O
10Gb	O
R720XD	O
2U	O
Rack	O
2012	O
C600	B-Architecture
2	O
LGA	B-Device
2011	I-Device
Xeon	B-Device
E5-2600or	O
E5-2600	O
v2	O
1.5	O
TB	O
24	O
,	O
DIMMDDR3	O
,	O
1600Mhz	O
38	O
TB	O
26	O
×	O
2.5	O
″	O
or	O
12	O
×	O
3.5	O
″	O
+	O
2	O
×	O
2.5	O
″	O
6	O
:	O
2	O
-	O
x16	O
FH/FL	O
,	O
1	O
-	O
x8	O
FH/FL	O
,	O
3	O
-	O
x8	O
HH/HL	O
Broadcom	O
or	O
Intel	O
4×	O
1Gb	O
or	O
2×	O
10Gb	O
R820Dell	O
website	O
:	O
Poweredge	B-Device
PowerEdge	B-Device
R820	O
rack	O
server	O
details	O
,	O
visited	O
06	O
February	O
2012	O
2U	O
Rack	O
2012	O
C600	B-Architecture
4	O
LGA	B-Device
2011	I-Device
Xeon	B-Device
E5-4600	O
1.5	O
TB	O
48	O
,	O
DIMMDDR3	O
1600MHz	O
16	O
TB	O
16	O
×	O
2.5	O
″	O
7	O
:	O
2	O
-	O
x16	O
HL/FH	O
,	O
1	O
-	O
x8	O
HL/FH	O
,	O
3	O
-	O
x8	O
HL/HH	O
,	O
1	O
-	O
x8	O
HL/FH	O
(	O
for	O
RAID	O
controller	O
)	O
Broadcom	O
or	O
Intel	O
4×	O
1Gb	O
or	O
2×	O
10Gb	O
R920Dell	O
website	O
:	O
Poweredge	B-Device
PowerEdge	B-Device
R920	O
rack	O
server	O
details	O
,	O
visited	O
05	O
May	O
2019	O
4U	O
Rack	O
2012	O
C602J	B-Architecture
4	O
LGA	B-Device
2011	I-Device
Xeon	B-Device
E7-2800/4800/8800	O
v2	O
6	O
TB	O
96	O
,	O
DIMMDDR3	O
1600MHz	O
28.8	O
TB	O
24	O
×	O
2.5	O
″	O
Broadcom	O
or	O
Intel	O
4×	O
1Gb	O
or	O
2×	O
10Gb	O
M420Dell	O
website	O
:	O
Poweredge	B-Device
M420	O
Technical	O
specifications	O
,	O
visited	O
17	O
July	O
2012	O
Blade1/4	O
height	O
2012	O
C600	B-Architecture
2	O
LGA	B-Device
1356	I-Device
Xeon	B-Device
E5-2400	O
192	O
GB	O
6	O
,	O
DIMMDDR3	O
,	O
1600Mhz	O
2	O
×	O
200	O
GB	O
2	O
×	O
1.8	O
"	O
Broadcom	O
2×	O
10	O
Gb	O
LOM	O
+1	O
Mezzanine	O
slot	O
M520Dell	O
website	O
:	O
Poweredge	B-Device
M520	O
Technical	O
specifications	O
,	O
visited	O
28	O
July	O
2012	O
Blade1/2	O
height	O
2012	O
C600	B-Architecture
2	O
LGA	B-Device
1356	I-Device
Xeon	B-Device
E5-2400	O
384	O
GB	O
12	O
,	O
DIMMDDR3	O
,	O
1600Mhz	O
2	O
×	O
SATA/SAS	O
HDD/SSD	O
2	O
×	O
2.5	O
″	O
Broadcom	O
or	O
Intel	O
on	O
board+2	O
Mezzanine	O
slots	O
M620Dell	O
website	O
:	O
Poweredge	B-Device
M620	O
Technical	O
specifications	O
,	O
visited	O
7	O
March	O
2012	O
Blade1/2	O
height	O
2012	O
C600	B-Architecture
2	O
LGA	B-Device
2011	I-Device
Xeon	B-Device
E5-2600	O
768	O
GB	O
24	O
,	O
DIMMDDR3	O
,	O
1600Mhz	O
2	O
×	O
2.5	O
″	O
Broadcom	O
or	O
Intel	O
on	O
board+2	O
Mezzanine	O
slots	O
M820Dell	O
website	O
:	O
Poweredge	B-Device
M820	O
Technical	O
specifications	O
,	O
visited	O
28	O
July	O
2012	O
Bladefull	O
height	O
2012	O
C600	B-Architecture
4	O
LGA	B-Device
2011	I-Device
Xeon	B-Device
E5-4600	O
1.5	O
TB	O
48	O
,	O
DIMMDDR3	O
,	O
1600MHz	O
4	O
×	O
SAS	O
HDD/SSDor	O
2	O
×	O
PCIe	O
flash	O
SSD	O
4	O
×	O
2.5	O
″	O
2×	O
10	O
Gb	O
Converged	O
Ethernet	O
Adaptor	O
on	O
board+2	O
Mezzanine	O
slots	O
C6220	O
Dell	O
website	O
:	O
Poweredge	B-Device
C6220	O
Technical	O
specifications	O
,	O
visited	O
28	O
July	O
2012	O
2U	O
Rack	O
2012	O
C600	B-Architecture
8	O
LGA	B-Device
2011	I-Device
Xeon	B-Device
E5-2600	O
2	O
TB	O
64	O
,	O
DIMMDDR3	O
,	O
1600MHz	O
48	O
TB	O
24	O
×	O
2.5	O
″	O
or	O
12	O
×	O
3.5	O
″	O
2×	O
1Gb	O
LOM	O
,	O
100	O
Mb	O
mgt	O
+	O
opt	O
.	O
</s>
<s>
Other	O
12th	O
Generation	O
servers	B-Application
,	O
which	O
are	O
comparable	O
in	O
capabilities	O
with	O
the	O
above	O
detailed	O
M	O
or	O
R	O
versions	O
of	O
the	O
same	O
model	O
number	O
,	O
are	O
:	O
</s>
<s>
up	O
to	O
8	O
x	O
10	O
Gb	O
+	O
12	O
x	O
1Gb	O
using	O
PCI	O
extension	O
slot	O
R630Dell	O
PowerEdge	B-Device
R630	O
Specification	O
Sheet	O
1U	O
Rack	O
2014Dell	O
13th	O
Generation	O
PowerEdge	B-Device
Server	O
Resources	O
,	O
Dell	O
website	O
.	O
</s>
<s>
4	O
×	O
10Gb	O
C4130Dell	O
EMC	O
PowerEdge	B-Device
C6420	O
Specification	O
Sheet	O
1U	O
Rack	O
2016	O
Intel	O
C612	O
2	O
Xeon	B-Device
E5	O
2600	O
v4	O
1TB	O
16	O
,	O
DDR4	O
up	O
to	O
2400MT/s	O
Up	O
to	O
4x	O
2.5	O
″	O
Drives	O
with	O
Tray	O
2x	O
PCIe	O
3.0	O
low	O
profile	O
Intel	O
H	O
OmniPath	O
Model	O
Chassis	O
Year	O
Chipset	O
CPU	O
(	O
No	O
.	O
)	O
</s>
<s>
In	O
July	O
2017	O
Dell	O
EMC	O
introduced	O
their	O
14th	O
generation	O
servers	B-Application
,	O
adding	O
support	O
for	O
latest	O
Intel	B-Device
Xeon	I-Device
Scalable	O
Processors	O
,	O
better	O
NVMe	B-Application
support	O
and	O
other	O
updates	O
.	O
</s>
<s>
4	O
x	O
10GbE	O
C6420Dell	O
EMC	O
PowerEdge	B-Device
C6420	O
Specification	O
Sheet	O
2U	O
Rack	O
2017	O
Model	O
Chassis	O
Year	O
Chipset	O
CPU	O
(	O
No	O
.	O
)	O
</s>
<s>
On	O
March	O
17	O
,	O
2021	O
,	O
Dell	O
officially	O
launched	O
their	O
15th	O
generation	O
PowerEdge	B-Device
servers	B-Application
with	O
some	O
models	O
already	O
available	O
in	O
2019	O
.	O
</s>
<s>
Independent	O
from	O
the	O
main	O
generations	O
of	O
servers	B-Application
a	O
value	O
line	O
was	O
produced	O
.	O
</s>
<s>
&	O
Socket	O
)	O
CPU	O
(	O
Type	O
)	O
RAM	O
(	O
Max	O
)	O
RAM	O
(	O
Type	O
)	O
Drive	O
bays	O
Comments	O
300	O
SCDell	O
PowerEdge	B-Device
300	O
Technical	O
Specification	O
Tower	O
Intel	O
440BX	O
Pentium	O
III	O
1	O
GB	O
4	O
,	O
ECC	B-Error_Name
reg	B-General_Concept
PC-100	O
1400	O
SCDell	O
PowerEdge	B-Device
1400SC	O
Technical	O
Specifications	O
Tower	O
2000	O
2	O
Pentium	O
III	O
2	O
GB	O
4	O
,	O
ECC	B-Error_Name
reg	B-General_Concept
PC-133	O
Ultra3	O
SCSI	O
controller	O
500	O
SCDell	O
PowerEdge	B-Device
500SC	O
Technical	O
Specification	O
Tower	O
2001PC	O
Mag	O
review	O
of	O
the	O
Dell	B-Device
PowerEdge	I-Device
500SC	O
ServerWorks	O
ServerSet	O
LE	O
3.0	O
1	O
Pentium	O
III	O
1.0	O
+	O
or	O
Celeron	O
800Mhz+	O
2	O
GB	O
4	O
,	O
ECC	B-Error_Name
PC-133	O
1500	O
SCDell	O
PowerEdge	B-Device
1500SC	O
Technical	O
Specifications	O
Tower	O
2	O
Pentium	O
III	O
1.1	O
GHz	O
4	O
GB	O
4	O
,	O
ECC	B-Error_Name
reg	B-General_Concept
PC-133	O
6	O
hot-swappable	O
Ultra3	O
SCSI	O
HDD	O
bays	O
600	O
SCDell	O
PowerEdge	B-Device
600SC	O
Specification	O
Sheet	O
Tower	O
2003	O
ServerWorks	O
GC-SL	O
1	O
Pentium	O
4	O
2.0	O
+	O
or	O
Celeron	O
1.7	O
+	O
4	O
GB	O
4	O
,	O
ECC	B-Error_Name
DDR	O
200	O
1600	O
SCDell	O
PowerEdge	B-Device
1600SC	O
Specification	O
Sheet	O
Tower	O
2004	O
ServerWorks	O
GC-SL	O
2	O
Xeon	B-Device
at	O
up	O
to	O
3.2	O
GHz	O
4	O
GB	O
4	O
,	O
ECC	B-Error_Name
DDR	O
266	O
420	O
SCDell	O
PowerEdge	B-Device
SC420	O
Specification	O
Sheet	O
Tower	O
2004	O
Intel	O
E7221	O
1	O
Pentium	O
4	O
or	O
Celeron	O
4	O
GB	O
4	O
,	O
ECC	B-Error_Name
DDR2	O
400	O
–	O
533	O
1420	O
SCDell	O
PowerEdge	B-Device
SC1420	O
Specification	O
Sheet	O
Tower	O
2004	O
Intel	O
E7520	O
2	O
Socket	B-Device
604	I-Device
Xeon	B-Device
,	O
800Mhz	O
FSB	O
8	O
GB	O
6	O
,	O
ECC	B-Error_Name
DDR2-400	O
(	O
3	O
)	O
internal	O
3.5	O
″( 2	O
)	O
5.25	O
externalup	O
to	O
4	O
HDD	O
1425	O
SCDell	O
PowerEdge	B-Device
SC1425	O
Technical	O
Specifications	O
1U	O
Rack	O
Intel	O
E7520	O
2	O
Xeon	B-Device
,	O
800Mhz	O
FSB	O
12	O
GB	O
6	O
,	O
ECC	B-Error_Name
DDR2	O
400	O
up	O
to	O
4	O
HDD	O
430	O
SCDell	O
PowerEdge	B-Device
SC430	O
Specification	O
Sheet	O
Tower	O
2005	O
Intel	O
E7230	O
1	O
LGA	B-Device
775	I-Device
Pentium	O
4	O
or	O
Celeron	O
D	O
4	O
GB	O
4	O
,	O
ECC	B-Error_Name
DDR2	O
533	O
(	O
2	O
)	O
ext	O
.	O
</s>
<s>
3.5	O
″	O
1430	O
SCDell	O
PowerEdge	B-Device
SC1430	O
Specification	O
Sheet	O
Tower	O
2006	O
Intel	O
5000V	O
2	O
LGA	B-Device
771	I-Device
Xeon	B-Device
5300	O
,	O
Xeon	B-Device
5100	O
,	O
Xeon	B-Device
5000	O
16	O
GB	O
4	O
,	O
ECC	B-Error_Name
DDR2	O
533-667	O
MHz	O
4	O
3.5	O
″	O
SAS	O
or	O
SATA	O
1435	O
SCDell	O
PowerEdge	B-Device
SC1435	O
Specification	O
Sheet	O
1U	O
Rack	O
2007	O
Broadcom	O
HT-2100	O
and	O
HT-1000	O
2	O
Socket	O
F	O
Opteron	O
2200	O
or	O
2300	O
32	O
GB	O
8	O
,	O
ECC	B-Error_Name
DDR2	O
667	O
1	O
slimline	O
bay	O
440	O
SCDell	O
PowerEdge	B-Device
SC440	O
Specification	O
Sheet	O
Tower	O
2006	O
Intel	O
3000	O
MCH	O
1	O
LGA	B-Device
775	I-Device
Xeon	B-Device
3000	O
,	O
Pentium	O
D	O
or	O
Celeron	O
D	O
8	O
GB	O
4	O
,	O
ECC	B-Error_Name
DDR2	O
533	O
–	O
667	O
(	O
2	O
)	O
ext	O
.	O
</s>
